Back to Top

Hi, Guest!

  LOKASI :  Kota Administrasi Jakarta Barat

Bergabung Selama :

BAGIKAN :   

Bagikan :
  • MIT480 series Telecoms insulation and continuity testers

MIT480 series Telecoms insulation and continuity testers

Update Terakhir
:
01 / 12 / 2019
Min. Pembelian
:
1 Lusin
Dilihat Sebanyak
:
31 kali
Harga
CALL
Bagikan
:

Perhatian !

Perusahaan ini terdaftar sebagai Free Member. Hindari melakukan pembayaran sebelum bertemu penjual atau melihat barang secara langsung. COD (Cash On Delivery) atau bertemu langsung dengan penjual merupakan metode transaksi aman yang kami sarankan.

Detail MIT480 Series Telecoms Insulation And Continuity Testers

SPECIFICATION All quoted accuracies are at + 20° C. Insulation Nominal test voltages MIT480 50 V, 100 V MIT481, 485 50 V, 100 V, 250 V, 500 V, 1000 V Insulation resistance range MIT480 10 G© MIT481, 485 200 G© Range Full Scale Accuracy All ranges ± 2% ± 2 digits up to 100 M© . Then: 1000 volts ± 3% ± 2 digits ± 0.2% per G© 500 volts. ± 3% ± 2 digits ± 0.4% per G© 250 volts. ± 3% ± 2 digits ± 0.8% per G© 100 volts. ± 3% ± 2 digits ± 2.0% per G© 50 volts. ± 3% ± 2 digits ± 4.0% per G© Analogue range 1 G© full scale Short Circuit Current: 2 mA + 0% -50% Terminal voltage: -0% + 20% ± 1 V Test Current on load: 1 mA at min. pass value of insulation specified in BS7671, HD384 and IEC364, 2 mA max. EN61557 Operating range: 0, 10 M© to 1, 00 G Leakage current range: 10 ¼ A 2000 ¼ A Leakage current: 10% ± 3 digits Voltage display: 3% ± 3 digits ± 0.5% of rated voltage Polarisation Index ( PI) : 10 min / 1minute ratio Dielectric Absorption Ratio ( DAR) : 60 sec / 30 sec ratio Notes: ( 1) All ranges measure from 0, 00 M© upwards. ( 2) Above specifications only apply when high quality silicone leads are being used. Continuity Measurement: 0, 01 © to 99, 9 © ( 0 to 100 © on analogue scale) Accuracy: ± 2% ± 2 digits ( 0 to 100 © ) Open circuit voltage: 5 V ± 1 V Test current: 205 mA ( – 0 mA + 20 mA) ( 0.01 © to 9.99 © ) 20mA ( ± 1 mA ) ( 10.0 © to 99.9 © ) Zero offset at probe tips: 0, 10 © typical Lead resistance zeroing: Up to 9, 99© Buzzer: Variable limit 1 © , 2 © , 5 © , 10 © , 20 © Resistance Measurement: 0, 01 k© to 1000 k© ( 0 to 1 M© on analogue scale) Accuracy: ± 3% ± 2 digits up to 50 k© then ± 2 digits Open circuit voltage: 5 V ± 1 V Short circuit current: 1.5 mA ± 0.2 mA Voltage range 0 to 600 V d.c. ± 2% ± 2 digits 10 mV to 600 V TRMS sinusoidal ( 40 to 400 Hz) ± 2% ± 2 digits 0 to 1000 V on Analogue scale Unspecified input level 0 - 10 mV ( 40 to 400 Hz) For non-sinusoidal waveforms additional specification apply: ± 3% ± 2 digits 101 mV to 600 V TRMS and ± 8% ± 2 digits 10 mV to 100 mV TRMS Default Voltmeter: Operates at > 25 V a.c. or d.c. on any range except OFF Frequency: 40-450 Hz ( 40 Hz - 99, 9 Hz) ± 0.5% ± 1 digit ( 100 Hz to 450 Hz) Capacitance measurement MIT481 and MIT485. Measurement range: 100 pF to 10 ¼ F Accuracy: ± 5.0% ± 2 digits Distance by capacitance: MIT481, MIT485 Arithmetic conversion from capacitance measurement on Default capacitance measurement: 50nF/ km Capacitance range: 40 nF/ km to 60 nF/ km Result storage Capacity: > 1000 test results Download: Bluetooth wireless Bluetooth Class: Class II Range: up to 10 m Power Supply: 5 x 1, 5 V cells type IEC LR6 ( AA, MN1500, HP7, AM3 R6HP) Alkaline NiMH rechargeable cells may be used. Battery life: 2200 insulation tests with duty cycle of 5 sec ON / 55 sec OFF @ 1000 V into 1 M© Dimensions Instrument: 220 x 92 x 50 mm ( 8.66 in. x 3.63 in. x 1.97 in.) Instrument + case: 456 x 178 x 89 mm ( 18 in. x 7 in. x 3.5 in.) Weight Instrument only: 590 gms, 775 gms with boot ( 20.73 oz., 27.22 oz.) Instrument plus case: 1.75kg ( 3.86 lb) Fuse Use only a 500 mA ( FF) 1000 V 32 x 6 mm ceramic fuse of high breaking capacity HBC 50 kA minimum. Glass fuses MUST NOT be fitted
Tampilkan Lebih Banyak