  • Industrial Multimeter Fluke 83

Industrial Multimeter Fluke 83

Update Terakhir
:
01 / 12 / 2019
Min. Pembelian
:
1 Lusin
Dilihat Sebanyak
:
9 kali
Harga
CALL
Bagikan
:

Perhatian !

Perusahaan ini terdaftar sebagai Free Member. Hindari melakukan pembayaran sebelum bertemu penjual atau melihat barang secara langsung. COD (Cash On Delivery) atau bertemu langsung dengan penjual merupakan metode transaksi aman yang kami sarankan.

Detail Industrial Multimeter Fluke 83

Industrial Multimeter Fluke 83V Specifications Voltage DC Maximum Voltage: 1000V Accuracy: Fluke 83 V: ± ( 0.1% + 1) Fluke 87 V: ± ( 0.05% + 1) Maximum Resolution: Fluke 83 V: 100 µ V Fluke 87 V: 10 µ V Voltage AC Maximum Voltage: 1000V Accuracy: Fluke 83 V: ± ( 0.5% + 2) Fluke 87 V: ± ( 0.7% + 2) True RMS AC Bandwidth Fluke 83 V: 5kHz Fluke 87 V: 20kHz* * with low pass filter; 3db @ 1kHz Maximum Resolution: 0.1 mV Current DC Maximum Amps: 10A ( 20 A for 30 seconds maximum) Amps Accuracy: Fluke 83 V: ± ( 0.4% + 2) Fluke 87 V: ± ( 0.2% + 2) Maximum Resolution: Fluke 83 V: 0.01 mA Fluke 87 V: 0.01 µ A Current AC Maximum Amps: 10A ( 20 A for 30 seconds maximum) Amps Accuracy: Fluke 83 V: ± ( 1.2% + 2) Fluke 87 V: ± ( 1.0% + 2) True RMS Maximum Resolution: 0.1 µ A Resistance Maximum Resistance: 50 M© Accuracy: Fluke 83 V: ± ( 0.4% + 1) Fluke 87 V: ± ( 0.2% + 1) Maximum Resolution: 0.1© Capacitance Maximum Capacitance 9, 999 µ F Accuracy ± ( 1% + 2) Maximum Resolution 0.01 nF Frequency Maximum Frequency 200 kHz Accuracy ± ( 0.005% + 1) Maximum Resolution 0.01 Hz Duty Cycle Maximum Duty Cycle 99.9% Accuracy ± ( 0.2% per khz + 0.1% ) Maximum Resolution 0.1% Temperature Measurement Fluke 87 V, 87 V/ E: -200.0° C - 1090° C -328.0° F - 1994.0° F excluding probe 80 BK Temperature Probe -40.0° C - 260° C -40.0° F - 500° F, 2.2° C or 2% whichever is greater Conductance Maximum Conductance 60.00 nS Accuracy ± ( 1.0% + 10) Maximum Resolution 0.01 nS Diode Range 3 V Resolution: 1 mV Accuracy: ± ( 2 % + 1) Duty Cycle Range Accuracy: Within ± ( 0.2% per kHz + 0.1 % ) Environmental Specifications Operating Temperature -20° C to + 55° C Storage Temperature -40° C to + 60° C Humidity ( Without Condensation) 0% - 90% ( 0° C - 35° C) 0% - 70% ( 35° C - 55° C) Operating Altitude 2000 m Safety Specifications Overvoltage category EN 61010-1 to 1000 V CAT III, 600V CAT IV Agency Approvals UL, CSA, Tý V, VDE listed Mechanical & General Specifications Size 201 x 98 x 52 mm ( with holster) Weight 355 g Weigh With Holster and Flex-Stand 624 g Display Digital: 6000 counts updates 4/ sec. ( Model 87 also has 19, 999 counts in high-resolution mode.) Analog: 32 segments, updates 40/ sec. Frequency: 19, 999 counts, updates 3/ sec at > 10 Hz. Warranty Lifetime Battery Life Alkaline: ~ 400 hours typical, without backlight Shock 1 Meter drop per IEC 61010-1: 2001 Vibration Per MIL-PRF-28800 for a Class 2 instrument
Tampilkan Lebih Banyak