Detail Industrial Multimeter Fluke 83
Industrial Multimeter Fluke 83V
Specifications
Voltage DC
Maximum Voltage: 1000V
Accuracy: Fluke 83 V: ± ( 0.1% + 1)
Fluke 87 V: ± ( 0.05% + 1)
Maximum Resolution: Fluke 83 V: 100 µ V
Fluke 87 V: 10 µ V
Voltage AC
Maximum Voltage: 1000V
Accuracy: Fluke 83 V: ± ( 0.5% + 2)
Fluke 87 V: ± ( 0.7% + 2) True RMS
AC Bandwidth Fluke 83 V: 5kHz
Fluke 87 V: 20kHz*
* with low pass filter; 3db @ 1kHz
Maximum Resolution: 0.1 mV
Current DC
Maximum Amps: 10A ( 20 A for 30 seconds maximum)
Amps Accuracy: Fluke 83 V: ± ( 0.4% + 2)
Fluke 87 V: ± ( 0.2% + 2)
Maximum Resolution: Fluke 83 V: 0.01 mA
Fluke 87 V: 0.01 µ A
Current AC
Maximum Amps: 10A ( 20 A for 30 seconds maximum)
Amps Accuracy: Fluke 83 V: ± ( 1.2% + 2)
Fluke 87 V: ± ( 1.0% + 2) True RMS
Maximum Resolution: 0.1 µ A
Resistance
Maximum Resistance: 50 M©
Accuracy: Fluke 83 V: ± ( 0.4% + 1)
Fluke 87 V: ± ( 0.2% + 1)
Maximum Resolution: 0.1©
Capacitance
Maximum Capacitance 9, 999 µ F
Accuracy ± ( 1% + 2)
Maximum Resolution 0.01 nF
Frequency
Maximum Frequency 200 kHz
Accuracy ± ( 0.005% + 1)
Maximum Resolution 0.01 Hz
Duty Cycle
Maximum Duty Cycle 99.9%
Accuracy ± ( 0.2% per khz + 0.1% )
Maximum Resolution 0.1%
Temperature Measurement
Fluke 87 V, 87 V/ E: -200.0° C - 1090° C
-328.0° F - 1994.0° F
excluding probe
80 BK Temperature Probe
-40.0° C - 260° C
-40.0° F - 500° F, 2.2° C or 2% whichever is greater
Conductance
Maximum Conductance 60.00 nS
Accuracy ± ( 1.0% + 10)
Maximum Resolution 0.01 nS
Diode
Range 3 V
Resolution: 1 mV
Accuracy: ± ( 2 % + 1)
Duty Cycle Range
Accuracy: Within ± ( 0.2% per kHz + 0.1 % )
Environmental Specifications
Operating Temperature
-20° C to + 55° C
Storage Temperature
-40° C to + 60° C
Humidity ( Without Condensation)
0% - 90% ( 0° C - 35° C)
0% - 70% ( 35° C - 55° C)
Operating Altitude
2000 m
Safety Specifications
Overvoltage category
EN 61010-1 to 1000 V CAT III, 600V CAT IV
Agency Approvals
UL, CSA, Tý V, VDE listed
Mechanical & General Specifications
Size
201 x 98 x 52 mm ( with holster)
Weight
355 g
Weigh With Holster and Flex-Stand
624 g
Display
Digital: 6000 counts updates 4/ sec.
( Model 87 also has 19, 999 counts in high-resolution mode.)
Analog: 32 segments, updates 40/ sec.
Frequency: 19, 999 counts, updates 3/ sec at > 10 Hz.
Warranty
Lifetime
Battery Life
Alkaline: ~ 400 hours typical, without backlight
Shock
1 Meter drop per IEC 61010-1: 2001
Vibration
Per MIL-PRF-28800 for a Class 2 instrument