  • Power Quality Analyzer Fluke 43B

Power Quality Analyzer Fluke 43B

Update Terakhir
:
01 / 12 / 2019
Min. Pembelian
:
1
Dilihat Sebanyak
:
22 kali

Harga

CALL
Bagikan
:

Perhatian !

Perusahaan ini terdaftar sebagai Free Member. Hindari melakukan pembayaran sebelum bertemu penjual atau melihat barang secara langsung. COD (Cash On Delivery) atau bertemu langsung dengan penjual merupakan metode transaksi aman yang kami sarankan.

Detail Power Quality Analyzer Fluke 43B

Power Quality Analyzer Fluke 43B Specifications Input Characteristics Input impedance 1 M© , 20 pF Voltage rating 600V rms, CAT III V/ A/ Hz Display True-rms voltage ( ac + dc) Ranges: 5.000 V, 50.00 V, 500.0 V, 1250 V* Accuracy: ± ( 1% + 10 counts) True-rms current ( ac + dc) Ranges: 50.00 A, 500.0 A, 5.000 kA, 50.00 kA, 1250 kA Accuracy: ± ( 1% + 10 counts) Frequency Ranges: 10.0 to 15.0 kHz Accuracy: ± ( [ % of reading] + [ counts] ) : 0.5% + 2 CF Crest factor Ranges: 1.0 - 10.0 Accuracy: ± ( 5% + 1 count) Power Display Watts, VA, VAR 1-phase and 3-phase, 3 conductor balanced loads Ranges: 250 W - 1.56 GW Accuracy: ± ( 4% + 4 counts) Fundamental Power Accuracy: ± ( 2 % + 6 counts) Total Power PF Power Factor Range: 0 - 1.0 Accuracy: ± 0.04 DPF Displacement Power Factor, Cos .F Range: 0.25 - 0.9 Accuracy: ± 0.04 Range: 0.90 - 1.0 Accuracy: ± 0.03 H2 Frequency Fundamental Ranges: 40.0 to 70.0 Hz Accuracy: ± ( [ % of reading] + [ counts] ) : 0.5% + 2 Harmonics Display Voltage, Current, Frequency Ranges: Fundamental to 51st harmonic Accuracy: Fundamental: VA ± ( 3% + 2 counts) W ± ( 5% + 2 counts) 2 to 31st harmonic: VA ± ( 5% + 3 counts) W ± ( 10% + 10 counts) 32 to 51st harmonic: VA ± ( 15% + 5 counts) W ± ( 30% + 5 counts Frequency Fundamental Ranges: 40 Hz to 70 Hz Accuracy: ± 0.25 Hz Phase Range: V, A ( between Fundamental & Harmonics) Accuracy: ± 3º to ± 15º Range: W ( between Voltage Fundamental & Current Harmonics) Accuracy: ± 5º to ± 15º K-factor ( Current and Power) Range: 1.0 to 30.0 Accuracy: ± 10% THD Total Harmonic Distortion Range: 0.00 - 99.99 Accuracy: ± ( 3% + 8 counts) Sags and Swells Recording times: 4 min to 16 days ( selectable) Vrms Actual, Vrms max, min( AC + DC) Ranges: 5.000V, 50.00V, 500.0V, 1250V* Accuracy: Readings ± ( 2% + 10 counts) ; Cursor readings ± ( 2% + 12 counts) Arms Actual, Arms max, min ( AC + DC) Ranges: 50.00A, 500.0A, 5.000 kA, 50.00 kA Accuracy: ± ( 2% + 10 counts) Transient Capture Minimum pulse width: 40 ns Useful bandwidth input 1: DC to 1 MHz Number of transients: 40 Voltage threshold settings: 20% , 50% , 100% , 200% above or below reference Reference signal: After START, the Vrms and frequency of the signal are measured. From these data a pure sinewave is calculated as reference for threshold setting. Vpeak min, Vpeak max at cursor: 10 V, 25 V, 50 V, 125 V, 250 V, 500 V, 1250 V Accuracy: ± 5% of full scale R, C, Diode, Continuity Resistance ranges: 500.0 © , 5.000 k© , 50.00 k© , 500.0 k© , 5.000 M© , 30.00 M© Resistance accuracy: ± ( 0.6% + 5 counts) Capacitance ranges: 50.00 nF, 500.0 nF, 5.000 µ F, 50.00 µ F, 500.0 µ F Capacitance accuracy: ± ( 2% + 10 counts) Diode Ranges: 0 to 3.000 V Diode voltage: Accuracy: ± ( 2% + 5 counts) Continuity: Beeper on at < 30 © ± 5 © Max current: 0.5 mA Temperature: ° C or ° F Inrush Current Inrush times: 1 s, 5 s, 10 s, 50 s, 100 s, 5 min Current ranges: 1 A, 5 A, 10 A, 50 A, 100 A, 500 A, 1000 A Cursor readings: A peak max at cursor 1 and cursor 2 Accuracy: ± 5% of full scale Time between cursors: 4 to 235 pixels ( 1 pixel = inrush time/ 250) Accuracy: ± ( 0.2% + 2 pixels) Temperature ( with accessory) Range: -100 ° C - 400 ° C Accuracy: ± ( 0.5% + 5 counts) Scope Display Measurements: dc, ac, ac+ dc, peak, peak-peak, frequency, duty cycle, phase, pulse width, crest factor Time ranges: 20 ns/ div to 60 s/ div Max sampling rate: 25 MS/ s Bandwidth Voltage channel [ 1] : 20 MHz at inputs, 1 MHz with TL24 Leads Current channel [ 2] : DC to 15 kHz at inputs, 10 kHz with i400s Current Clamp Coupling: AC, DC ( 10 Hz - 3 dB) Vertical sensitivity: 5 mV/ div to 500V/ div Vertical resolution: 8 bit ( 256 levels) Record length: 512 samples per channel Base ranges: 60 S/ div to 20 nS/ div ± ( 0.4% + 1 pixel) Timebase modes: Normal, roll, single Pre-trigger: Up to 10 divisions Trigger Source: Input 1 or Input 2 or automatic selection Trigger Mode: Automatic Connect-and-View™ , Free Run, and Single Shot Connect-and-View™ : Advanced automatic triggering that recognizes signal patterns Automatically adjusts triggering, timebase and amplitude and displays stable pictures Memories 20 ( screens, settings, data) Recording Recording times: 4 min to 16 days ( selectable) Parameters: Choose one or two parameters from one of the groups below: Volts/ Ampè res/ Hertz Power: Watts, VA, VAR, PF, DPF, Frequency Harmonics, THD, Volts ( Fund. & Harmonic) , Ampè res ( F& H) Watts( F& H) Frequency ( H) , % ( H) of total, Phase( H) , KF Temperature Resistance: Resistance, Diode, Continuity, Capacitance Scope: DC Voltage, DC Current, AC Voltage, AC Current, Frequency, Pulse Width + or -, Phase, Duty cycle + or -, Peak max, Peak min, Peak min-max, Crest Factor Note * Rated EN 61010-1 600 V CAT III CSA
Tampilkan Lebih Banyak